PV cables can generally be directly buried, but there are specific requirements and considerations to ensure their proper operation and safety:
· Cable Type Selection: It is necessary to choose PV cables with appropriate sheath materials and protection levels. For example, some PV cables are designed with a special polyethylene - based sheath material, which has good anti - corrosion and anti - moisture - penetration properties, suitable for direct burial.
· Burial Depth: The burial depth should meet the relevant standards and requirements. Usually, the burial depth is about 0.8 - 1.0 meters to avoid the cable being affected by surface activities and temperature changes. In agricultural areas or places with heavy traffic, a greater burial depth may be required.
· Ground Conditions: The soil where the cable is buried should be free of sharp objects and corrosive substances to prevent damage to the cable sheath. If the soil is too wet or has a high salt content, appropriate anti - corrosion measures need to be taken, such as using a cable with a double - layer sheath or applying an anti - corrosion coating.
· Protection Tubes: In some cases, it is advisable to place the PV cable in a protection tube before burial. The protection tube can be made of materials such as PVC or steel, which can provide additional protection for the cable and facilitate future maintenance and replacement.
· Marking: After burying the PV cable, clear marking should be set on the ground to indicate the location of the cable to avoid accidental damage during future excavation or construction.
During the installation and direct burial of PV cables, it is necessary to strictly follow the relevant installation specifications and standards to ensure the safe and reliable operation of the cable. If in doubt, it is recommended to consult a professional electrician or relevant technical expert.
The specific requirements for the burial depth of PV cables are as follows:
· General situation: The depth of directly buried cables should be no less than 0.7m. In agricultural areas or other cultivated areas, the depth should be appropriately increased to more than 1m to prevent the cables from being damaged by farming machinery.
· Special cases: When the cable crosses railway, highway, urban street, or field - area road, it should be laid in a solid protection tube or tunnel. The two ends of the cable tube should extend 1m on both sides of the roadbed and 0.5m outside the drainage ditch, and the burial depth should not be lower than 1m below the road surface. When the cable is introduced into a building, intersects with an underground building, or bypasses an underground building, it can be laid shallowly, but protective measures should be taken.
If you have further questions or need more details on specific aspects of this topic, feel free to ask!